Description
Product Name: Reset Module 80 110
Supply Ability:
Related proudcts
Specifications 80 110
Price Term:
Port of loading:
Minimum Order
Unit Price:

Reset Module 80 110
for reset of the error messages
of all Planar4 modules of one subrack
With renunciation of the communication within the Planar4 System, instead
of the communication module (with built-in reset pushbutton) this
simple reset module can be used.
With the Reset pushbutton the error messages (ERR) on the Planar4 modules
(since AS 10) of one subrack can be ackowledged via the communication
if the triggering error (defect of module) is no longer present.
The reset has no effects on the safety-related function of the Planar4 modules,
i. e. there will not be triggered a reset of the control.
Up to 20 modules of the Planar4 System can be connected to the channels
(z2-z4, z6-z8, ... d22-d24) for internal communication. For this application
the Planar4 subracks with bus PCB should be used which already
contain the necessary connections. The module locations 1...20 of these
subracks are provided for Planar4 modules, the 21st location is reserved
for the reset module or a communication module.
RDY (Ready) indicates the available power supply voltage.
Operating data 24 V DC / 12 mA
***ce requirement 3 U high, 4 SU
RDY
+ - + - + - + - + - + - + - + - + -
Steuerlogik / Control logic
z2
z26
b26
z8
b4
d4
d24
z4
z28
b28
b6
d6
z6
b2
d2
d22
b8
d8
EL+
Ld30
z32 z30
b32
d32
1 2 7 8 9 14 15 16 20 Kanal
Channel
Reset
80 110
RDY
Reset
80 110 (0128)
2/2
For your notesReset Module 80 110
for reset of the error messages
of all Planar4 modules of one subrack
With renunciation of the communication within the Planar4 System, instead
of the communication module (with built-in reset pushbutton) this
simple reset module can be used.
With the Reset pushbutton the error messages (ERR) on the Planar4 modules
(since AS 10) of one subrack can be ackowledged via the communication
if the triggering error (defect of module) is no longer present.
The reset has no effects on the safety-related function of the Planar4 modules,
i. e. there will not be triggered a reset of the co

Contact Us
Company: Asia Science&Technology Co***ny Limited
Contact: Mr. Ethan Wen
Address: Unit 04, 7/ F, Bright Way Tower,No. 33 Mong Kok Road, Kowloon, HK.
Postcode:
Tel: 00852-27935511
Fax: 00852-35902333
E-mail:         


Copyright© Asia Science&Technology Co***ny Limited All Rights Reserved.